Do You Have Any Inquiries?
• Removal of previously applied epoxy flooring that failed prematurely due to poor execution.
• Application of epoxy flooring system across the two garage levels.
• Installation of polyurethane coating on the ramps for skid resistance.
• Level correction of the garage slab using cementitious self-leveling mortar.

1. The garage was previously coated with epoxy but failed within a short period, requiring full removal.
2: Tight execution schedule for delivering the two-level garage.
3: Floor levels needed correction before re-application.
The old epoxy was completely removed, surfaces were corrected using MasterTop 548 self-leveling mortar with MasterTop 500 bonding agent, followed by application of the new epoxy system. Polyurethane coatings were applied on the ramps to ensure durability and safety. The project was completed on time and handed over successfully.