Do You Have Any Inquiries?
• Internal waterproofing of the hotel’s main water tank with non-toxic epoxy coating suitable for potable water.
• Repair of defective concrete, honeycombing, and surface irregularities prior to waterproofing.
• Application of cementitious repair grouts and bonding mortars to ensure a sound substrate.
• Final application of multi-layer epoxy and cementitious waterproofing system.

The tank concrete had severe defects (honeycombs, cracks, uneven surfaces). Traditional plastering would have been very costly and time consuming. In addition, the hotel was operating and depending on temporary side tanks, so speed was critical.
The team carried out fast-track surface repairs using Master Builders Solutions systems, applied non-toxic epoxy/cementitious waterproofing, and delivered the tank back to service in a short timeline with significant cost savings compared to conventional methods.